Description
Vacuum switches are a type of pressure switch that functions in the vacuum end of the pressure. Their primary purpose is to monitor vacuum status and open or close a connection when there is a change in the vacuum level.
Specifications
General Specifications
Model |
V16 – PNP |
V16 – NPN |
Applicable fluid |
Filtered air, Non-corrosive & flammable gas |
Pressure range |
-101.0 ~ 0 kPa |
Withstand pressure |
300 kPa |
Pressure port |
1/8″ PT, M5 female |
Powel supply voltage |
12-24VDC ±10%, Ripple(P-P) ±10% or less |
Powel consumption |
Max.2l mA |
Max.25 mA |
Output |
1-PNP, Max load current: 80 mA |
2-NPN, Max load current: 80 mA |
Enviroment |
Repeatability |
≤±1% F.S. |
Response tlme |
≤5 ms |
Protection structure |
IP40 |
Operating temp. |
Operation: 0~50℃, Storage:-20~60℃ (No condensation or freezing) |
Operating humidity |
Operation/Storage: 35~85% RH (No condensation) |
Vibration resistance |
Total amplitude 1.5mm or 10G, 10~55 Hz scan for 1-min, 2-hour each direction of X, Y, and Z |
Shock resistance |
980 m/s² (100G), 3-time each in direction of X, Y, and Z |
Temperature characteristic |
≤±3% F.S. at temp. (25℃) |
Hysteresis mode |
1~10% pressure (Adjustable) |
3% F.S. or less (Fixed) |
Switch ON indicator |
Out-1 red |
Out-1 red/ Out-2 green |
Cable |
Oil-resistance 3-core 1 m lead wire |
Oil-resistance 4-core 1 m lead wire |
Weight |
50 g (Including 1 m lead wire) |
NPN and Analog output |
|
PNP and Analog output |
|
Dimensions
Order Numbers
V16 series switches
Part Number |
Description |
V16-1-02 |
Vacuum switch, No-display, PNP 1-output |
V16-1-03 |
Vacuum switch, No-display, NPN 2-output |
Downloads
Catalog & CAD filesV16 Switches |
|
---|
V16 Switches |
|
---|
V16 Switches |
|
---|